Influence reduction of piroelektric charges on measuring amplifiers functioning

  • V. I. Startsev Odessa National Polytechnic University, Ukraine
  • Ju. S. Yampolsky Odessa National Polytechnic University, Ukraine
  • A. P. Kutsenko Odessa National Polytechnic University, Ukraine
Keywords: charge-sensitive amplifier, piezoelectric sensor, pyroelectricity

Abstract

The article observes sсhemotehnic methods of influence reduction of piroelektric effect on charge-sensitive amplifiers functioning. The taken action allows to essentially reduce the influence of piroelektric currents caused by temperature change on the level of output tension of charge-sensitive amplifiers.

Published
2010-08-28
How to Cite
Startsev, V. I., Yampolsky, J. S., & Kutsenko, A. P. (2010). Influence reduction of piroelektric charges on measuring amplifiers functioning. Technology and Design in Electronic Equipment, (3), 58-60. Retrieved from https://tkea.com.ua/index.php/journal/article/view/TKEA2010.3.58