Generator for electrotherapy and stimulation of human nerve centers

  • V. E. Babelyuk "Moldova" Resort, Truskavets, Ukraine
  • Yu. G. Dobrovolsky SKB "PDK"; Yurii Fedkovych Chernivtsi National University, Chernivtsy, Ukraine https://orcid.org/0000-0003-0626-0594
  • I. L. Popovich Bogomoletz Institute of Physiology of NAS of Ukraine, Kyiv, Ukraine
  • I. G. Korsunskiy SKB "PDK", Чернівці, Україна
Keywords: generator, electrostimulation, nerve center, current pulse, frequency beats

Abstract

A generator for electrotherapy and stimulation of human VEB-1 nerve centers has been developed. The device's robots are based on stimulation of the patient by current pulses. Frequency beat method is used. The accuracy of maintaining the stimulation frequency is not more than 0.001 Hz. The carrier frequency of the working current pulses corresponds to the 32nd harmonic of the frequency of the frequency pulse of the operating pulses. The clinical tests of the VEB-1 generator were carried out, showing the ego efficiency in twenty characteristic health indicators.

References

Top 10 Medical Device Trends to Watch in 2017, Dec 27, 2016, 4 p.

Powell J., D Pandyan., Granat M., Cameron M., Stott D. Electrical Stimulation of Wrist Extensors in Poststroke Hemiplegia. Stroke: Journal of the American Heart Association, 1999, no 30 (7), pp. 1384–1389.

Kern H., Carraro U., Adami N., Biral D., Hofer C., Forstner C., Mödlin M., Vogelauer M., Pond A., Boncompagni S., Paolini C., Mayr W., Protasi F., Zampieri S. Home-based functional electrical stimulation rescues permanently denervated muscles in paraplegic patients with complete lower motor neuron lesion. Neurorehabil Neural Repair, 2010, no. 24 (8), pp. 709–721.

Chantraine A., Baribeault A., Uebelhart D., Gremion G. Shoulder Pain and Dysfunction in Hemiplegia: Effects of Functional Electrical Stimulation. Archives of Physical Medicine and Rehabilitation, 1999, no 80, pp. 328–331.

Konoplev S.P., Konopleva T.P. [Method of low-frequency electromagnetic therapy and a device for its implementation]. Patent RF, no 2164424, 2001 (Rus)

Kaufmann W. [Device for generating a magnetic field with a duplicated system and an interference protection device]. Patent FRG, no 4238745, 1994. (Rus)

Vasilieva L.V., Gorkovenko I. A. [Low-frequency electromagnetic therapy alternative to antibiotic therapy of ulcerative lesions of the gastrointestinal tract]. Vestneyk novykh meditsinskikh tekhnologii, 2010 Iss. 2. vol. XX, pp. 185-187. (Rus)

[The device of pulse electromagnetic therapy]. Vestneyk sportivnykh innovatsii, 2012, no 38, p. 6. (Rus)

Sharifov S.K., Soloviev S.V. [Device for electromagnetic therapy]. Patent RF, no. 101365, 2011. (Rus)

Turchinov A.N., Volkovynskaia A.A. [Portable device for electrotherapy and stimulation], Patent UA, no. 49957, 2010. (Rus)

Babelyuk N. V., Babelyuk V. E., Dubkova G. I., Kikhtan V. V., Musienko V. Yu., Gubitsky V. Y., Dobrovolsky Yu. G., Korsunsky І. G., Kovbasnyuk M. M., Korolishin T. A., Popovich I. L. [The modularity of functional systems is practically healthy for people with a course of electrostimulation]. Proceed. of the IХ Mizhnarodnii simpozium «Aktual`nye problemy biofizicheskoi meditsiny», Ukraine, Kyiv, 2016. pp. 10-11. (Ukr)

Babelyuk N. V., Babelyuk V. E., Dubkova G. I., Korolyshyn T. A., Kihtan V. V., Dobrovolsky Yu. G., Korsun I. G., Kovbasnyuk M. M. [Electrical stimulation device “ES-01.9 WEB» activates some functional systems of the body healthy men]. Proceed. of the XIV International Scientific Conference «Valeologiya: current status, trends and prospects of development», Ukraine, Kharkiv, 2016, pp.198-190. (Ukr)

Byshop R. [Fluctuations]. Moscow, Nauka, 1986, 190 p. (Rus)

Vinnitsky A. S. [Autonomous radio systems]. Мoscow, Radio and communication, 1986, pp.173-190. (Rus)

Published
2017-04-27