Silicon whisker crystal-based strain gauges for low-temperature applications.
Keywords:
silicon, strain gauge, cryogenic temperatures, liquid nitrogen, liquid helium
Abstract
The strain characteristics of p-type silicon whisker crystals have been investigated in the temperature range of 4.2 – 300 K. On their basis, strain gauges with an anomalously high gauge factor at 4.2 K have been developed for measuring deformation in various materials at cryogenic temperatures, as well as strain gauges operable at helium temperatures in strong magnetic fields
Published
2008-08-30
How to Cite
Druzhinin, A. A., Maryamova, I. I., Kutrakov, A. P., & Pavlovskyy, I. V. (2008). Silicon whisker crystal-based strain gauges for low-temperature applications. Technology and Design in Electronic Equipment, (4), 26-30. Retrieved from https://tkea.com.ua/index.php/journal/article/view/TKEA2008.4.26